Insulation Failure of Inter-Turn Insulation in Inverter-Fed Traction Motor
Paper
Paper/Presentation Title | Insulation Failure of Inter-Turn Insulation in Inverter-Fed Traction Motor |
---|---|
Presentation Type | Paper |
Authors | Luo, Y. (Author), Wu, G. N. (Author), Wang, P. (Author), Cao, K. J. (Author) and Cui, Y. (Author) |
Journal or Proceedings Title | Proceedings of the IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2012) |
ERA Conference ID | 72285 |
Number of Pages | 4 |
Year | 2012 |
Place of Publication | Montreal, Canada |
ISBN | 9781467312530 |
9781467312523 | |
Digital Object Identifier (DOI) | https://doi.org/10.1109/CEIDP.2012.6378909 |
Web Address (URL) of Paper | https://ieeexplore.ieee.org/document/6378909 |
Conference/Event | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2012) |
IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) | |
Event Details | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2012) Event Date 14 to end of 17 Oct 2012 Event Location Montreal, Canada |
Event Details | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) CEIDP |
Abstract | Partial discharge (PD) under a sequence of high-frequency pulse is one of the key factors which lead to premature failure of turn insulation of inverter-fed motors. Aging experiments for turn insulation samples under bipolar continuous square impulse voltage were done. The number and mean quantity of PDs under impulse voltage has been studied. By means of scanning electron microscope (SEM), the microcosmic morphology of surface of turn insulation was analyzed. The results reveal that the relationship of PD parameters (PD number and mean PD quantity) and aging time is complicated. The damage to polyimide nano-composite film structure is concentrated on the degradation of polymer matrix in the presence of PDs. The residual nano-fillers remained on the surface and formed a screen layer to resist the further damage of PDs. It is the symbol of faults expanding rapidly when the floccules and voids formed on the surface, which means insulation failure. |
Keywords | Aging time; Film structure; High-frequency pulse; Impulse voltage; Insulation failures; Inverter fed motors; Nano-fillers; PD parameters; Premature failures |
ANZSRC Field of Research 2020 | 400803. Electrical energy generation (incl. renewables, excl. photovoltaics) |
Public Notes | There are no files associated with this item. |
Byline Affiliations | Southwest Jiaotong University, China |
Institution of Origin | University of Southern Queensland |
https://research.usq.edu.au/item/q7w60/insulation-failure-of-inter-turn-insulation-in-inverter-fed-traction-motor
43
total views0
total downloads4