Possible Mechanism of Electrical Treeing and Breakdown for Polyimide Nanocomposite Film Used in Inverter-Fed Motor
Paper
Paper/Presentation Title | Possible Mechanism of Electrical Treeing and Breakdown for Polyimide Nanocomposite Film Used in Inverter-Fed Motor |
---|---|
Presentation Type | Paper |
Authors | Cui, Yi (Author), Wu, Guangning (Author), Wu, Chao (Author) and Luo, Yang (Author) |
Journal or Proceedings Title | Proceedings of the IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 20130 |
ERA Conference ID | 72285 |
Number of Pages | 4 |
Year | 2010 |
Place of Publication | West Lafayette, India |
ISBN | 9781424494682 |
9781424494712 | |
Digital Object Identifier (DOI) | https://doi.org/10.1109/CEIDP.2010.5724102 |
Web Address (URL) of Paper | https://ieeexplore.ieee.org/document/5724102 |
Conference/Event | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2010) |
IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) | |
Event Details | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP 2010) Event Date 17 to end of 20 Oct 2010 Event Location West Lafayette, India |
Event Details | IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) CEIDP |
Abstract | The failure of magnet wires used in inter-turn insulation of inverter-fed motor winding is the main cause which leads to the motor insulation breakdown. This paper conducted electrical tree breakdown experiments on magnet wire insulating film (FCR 100) used in the inter-turn insulation of JD117 inverter-fed motor and meanwhile combining with energy spectrum analysis and scanning electrical microscope (SEM), by which type and content of elements, breakdown main body and electrical tree channel could be clearly observed, the corresponding failure mechanisms were analyzed. The experiment results reveal that all the breakdown main bodies are located at the pointedness and insulation joint of magnet wires, of which dielectric strength is relatively lower; they are the insulation 'weak point', which should be paid enough attention and strengthened at the manufacturing period. The electrical tree breakdown time is quite long and the life span of magnet wire is 11 hours. The electrical breakdown strength of envelope is very low when containing metal impurity. It is also found that the aluminum occupies the highest content tested by energy spectrum analysis. |
Keywords | Breakdown; Electrical tree; Inverter-fed motor; Magnet wire |
ANZSRC Field of Research 2020 | 400803. Electrical energy generation (incl. renewables, excl. photovoltaics) |
Public Notes | There are no files associated with this item. |
Byline Affiliations | Southwest Jiaotong University, China |
Institution of Origin | University of Southern Queensland |
https://research.usq.edu.au/item/q7w74/possible-mechanism-of-electrical-treeing-and-breakdown-for-polyimide-nanocomposite-film-used-in-inverter-fed-motor
34
total views0
total downloads4
views this month0
downloads this month