400305. Biomedical instrumentation


Title400305. Biomedical instrumentation
Parent4003. Biomedical engineering

Latest research outputs

Sort by Date Title
Botulinum toxin A dissolving microneedles for hyperhidrosis treatment: design, formulation and in vivo evaluation
Malek-Khatabi, Atefeh, Rad-Malekshahi, Mazda, Shafiei, Morvarid, Sharifi, Fatemeh, Motasadizadeh, Hamidreza, Ebrahiminejad, Vahid, Rad-Malekshahi, Mazdak, Akbarijavar, Hamid and Faraji Rad, Zahra. 2023. "Botulinum toxin A dissolving microneedles for hyperhidrosis treatment: design, formulation and in vivo evaluation." Biomaterials Science. 11 (24), pp. 7784-7804. https://doi.org/10.1039/d3bm01301d

Article

An overview of microneedle applications, materials, and fabrication methods
Faraji Rad, Zahra, Prewett, Philip and Davies, Graham. 2021. "An overview of microneedle applications, materials, and fabrication methods." Beilstein Journal of Nanotechnology. 12, pp. 1034-1046. https://doi.org/10.3762/bjnano.12.77

Article

Optical coherence elastography for the measurement of anterior segment biomechanical properties
Quince, Zachery David. 2022. Optical coherence elastography for the measurement of anterior segment biomechanical properties. PhD Thesis Doctor of Philosophy . Queensland University of Technology . https://doi.org/10.5204/thesis.eprints.236255

PhD Thesis

A Dielectric Elastomer-Based Multimodal Capacitive Sensor
Zhu, Yuting, Giffney, Tim and Aw, Kean. 2022. "A Dielectric Elastomer-Based Multimodal Capacitive Sensor ." Sensors. 22 (2). https://doi.org/10.3390/s22020622

Article

Reliability of a close-range photogrammetry technique to measure ankle kinematics during active range of motion in place
Al-Kharaz, Ali A. and Chong, Albert. 2021. "Reliability of a close-range photogrammetry technique to measure ankle kinematics during active range of motion in place." The Foot. 46, pp. 1-5. https://doi.org/10.1016/j.foot.2020.101763

Article

Depth of anaesthesia assessment using interval second-order difference plot and permutation entropy techniques
Li, Tianning and Wen, Peng. 2017. "Depth of anaesthesia assessment using interval second-order difference plot and permutation entropy techniques." IET Signal Processing. 11 (2), pp. 221-227. https://doi.org/10.1049/iet-spr.2015.0114

Article

Evidence of tactile dominance when integrated with proprioception – application to haptic feedback interfaces
Gildersleeve, Matthew. 2012. "Evidence of tactile dominance when integrated with proprioception – application to haptic feedback interfaces." Procedia Engineering. 41, pp. 1035-1043.

Article

Mutual enlightenment: augmenting human factors research in surgical robotics
Gildersleeve, Matthew. 2013. "Mutual enlightenment: augmenting human factors research in surgical robotics." IEEE Pulse. 4 (2), pp. 26-31.

Article

Infrared needle mapping to assist biopsy procedures and training
Shar, Bruce, Leis, John and Coucher, John. 2018. "Infrared needle mapping to assist biopsy procedures and training." Healthcare Technology Letters. 5 (2), pp. 65-69. https://doi.org/10.1049/htl.2017.0045

Article

Real time depth of anaesthesia monitoring through electroencephalogram (EEG) signal analysis based on Bayesian method and analytical technique
Palendeng, Mario Elvis. 2015. Real time depth of anaesthesia monitoring through electroencephalogram (EEG) signal analysis based on Bayesian method and analytical technique. PhD Thesis Doctor of Philosophy. University of Southern Queensland.

PhD Thesis

Depth of anaesthesia assessment based on adult electroencephalograph beta frequency band
Li, Tianning and Wen, Peng. 2016. "Depth of anaesthesia assessment based on adult electroencephalograph beta frequency band." Physical and Engineering Sciences in Medicine. 39 (3), pp. 773-781. https://doi.org/10.1007/s13246-016-0459-5

Article

Depth of anaesthesia monitors and the latest algorithms
Li, Tianning and Li, Yan. 2014. "Depth of anaesthesia monitors and the latest algorithms." Asian Pacific Journal of Tropical Medicine. 7 (6), pp. 429-437. https://doi.org/10.1016/S1995-7645(14)60070-5

Article

Investigation of unstabilized polyvinyl chloride (PVC) for use as a long-term UV dosimeter: preliminary results
Amar, Abdurazaq and Parisi, Alfio V.. 2012. "Investigation of unstabilized polyvinyl chloride (PVC) for use as a long-term UV dosimeter: preliminary results." 37th Annual Conference of the Australasian Radiation Protection Society (ARPS 2012): Radiation Safety: Bridging the Gap. Sydney, Australia 14 - 17 Oct 2012 Hobart, Australia.

Presentation

Feasibility study of a hand guided robotic drill for cochleostomy
Brett, Peter, Du, Xinli, Zoka-Assadi, Masoud, Coulson, Chris, Reid, Andrew and Proops, David. 2014. "Feasibility study of a hand guided robotic drill for cochleostomy." BioMed Research International. 2014. https://doi.org/10.1155/2014/656325

Article

Depth of anaesthesia assessment based on time and frequency features of simplified electroencephalogram (EEG)
Li, Tianning. 2015. Depth of anaesthesia assessment based on time and frequency features of simplified electroencephalogram (EEG). PhD Thesis Doctor of Philosophy. University of Southern Queensland.

PhD Thesis

Noise reduction method for the heart sound records from digital stethoscope
Chen, Haoyu. 2015. Noise reduction method for the heart sound records from digital stethoscope. PhD Thesis Doctor of Philosophy. University of Southern Queensland.

PhD Thesis

Computer-based method of determining the path of a HIFU beam through tissue layers from medical images to improve cancer treatment
McCarthy, E. and Pather, S.. 2008. "Computer-based method of determining the path of a HIFU beam through tissue layers from medical images to improve cancer treatment." Billingsley, John and Bradbeer, Robin (ed.) Mechatronics and machine vision in practice . Berlin, Germany. Springer. pp. 289-302

Edited book (chapter)

Real-time depth of anaesthesia assessment using strong analytical signal transform technique
Palendeng, Mario Elvis, Wen, Peng and Li, Yan. 2014. "Real-time depth of anaesthesia assessment using strong analytical signal transform technique." Physical and Engineering Sciences in Medicine. 37 (4), pp. 723-730. https://doi.org/10.1007/s13246-014-0309-2

Article

Anaesthetic EEG signal denoise using improved nonlocal mean methods
Li, Tianning, Wen, Peng and Jayamaha, Sophie. 2014. "Anaesthetic EEG signal denoise using improved nonlocal mean methods." Physical and Engineering Sciences in Medicine. 37 (2), pp. 431-437. https://doi.org/10.1007/s13246-014-0263-z

Article

Investigation on the capability of polysulphone for measuring biologically effective solar UV exposures
Siani, Anna Maria, Casale, Guiseppe R., Modesti, Sarah, Parisi, Alfio V. and Colosimo, Alfredo. 2014. "Investigation on the capability of polysulphone for measuring biologically effective solar UV exposures." Photochemical and Photobiological Sciences. 13 (3), pp. 521-530. https://doi.org/10.1039/c3pp50267h

Article

Assessment of electric field distribution in anisotropic cortical and subcortical regions under the influence of tDCS
Shahid, Salman, Wen, Peng and Ahfock, Tony. 2014. "Assessment of electric field distribution in anisotropic cortical and subcortical regions under the influence of tDCS." Bioelectromagnetics. 35 (1), pp. 41-57. https://doi.org/10.1002/bem.21814

Article

Investigation of core muscle function through electromyography activities in healthy young men
Tan, Sijie, Cao, Liquan, Schoenfisch, Whitney and Wang, Jianxiong. 2013. "Investigation of core muscle function through electromyography activities in healthy young men." Journal of Exercise Physiology. 16 (1), pp. 45-52.

Article

Reliability of a high accuracy image-based system for 3D modelling of the medial longitudinal arch during gait
Alshadli, Duaa, Chong, Albert K., McDougall, Kevin, Al-Baghdadi, Jasim, Milburn, Peter and Newsham-West, Richard. 2013. "Reliability of a high accuracy image-based system for 3D modelling of the medial longitudinal arch during gait." Rahman, Alias Abdul, Boguslawski, Pawel, Gold, Christopher and Said, Mohamad Nor (ed.) International Workshop on Geoinformation Advances 2012. Johor Bahru, Malaysia 07 - 08 Nov 2012 Berlin, Germany. https://doi.org/10.1007/978-3-642-36379-5_6

Paper

Low-cost compact high-speed camera for human motion study
Chong, Albert K. and Majid, Zulkepli. 2013. "Low-cost compact high-speed camera for human motion study ." Rahman, Alias Abdul, Boguslawski, Pawel and Gold, Christopher (ed.) International Workshop on Geoinformation Advances 2012. Johor Bahru, Malaysia 07 - 08 Nov 2012 Berlin, Germany.

Paper

Infrared camera imaging algorithm to augment CT-assisted biopsy procedures
Leis, John and Sharifi, Behrooz. 2012. "Infrared camera imaging algorithm to augment CT-assisted biopsy procedures." Wysocki, Beata J. and Wysocki, Tadeusz A. (ed.) 2012 6th International Conference on Signal Processing and Communication Systems (ICSPCS 2012). Gold Coast, Australia 12 - 14 Dec 2012 United States. IEEE (Institute of Electrical and Electronics Engineers). https://doi.org/10.1109/ICSPCS.2012.6507977

Paper

Consciousness, EEG and depth of anaesthesia monitoring
Wen, Peng. 2012. "Consciousness, EEG and depth of anaesthesia monitoring." Physical and Engineering Sciences in Medicine. 35 (4), pp. 389-392. https://doi.org/10.1007/s13246-012-0176-7

Article

Exploiting HD camcorders for close-up human movement applications
Chong, Albert K.. 2012. "Exploiting HD camcorders for close-up human movement applications." The Photogrammetric Record. 27 (138), pp. 227-237. https://doi.org/10.1111/j.1477-9730.2012.00673.x

Article

Mean exposure fractions of human body solar UV exposure patterns for application in different ambient climates
Downs, Nathan and Parisi, Alfio. 2012. "Mean exposure fractions of human body solar UV exposure patterns for application in different ambient climates." Photochemistry and Photobiology. 88 (1), pp. 223-226. https://doi.org/10.1111/j.1751-1097.2011.01025.x

Article

A dense surface modelling technique for foot surface imaging
Al-Baghdadi, Jasim Ahmed Ali, Chong, Albert K., McDougall, Kevin, Alshadli, Duaa, Milburn, Peter and Newsham-West, Richard. 2011. "A dense surface modelling technique for foot surface imaging." Hock, Barbara (ed.) 2011 Surveying and Spatial Sciences Conference: Innovation in Action: Working Smarter (SSSC 2011). Wellington, New Zealand 21 - 25 Nov 2011 Rotorua, New Zealand.

Paper

Multisensory integration weightings underlying haptic feedback in laparoscopic surgery
Gildersleeve, Matthew. 2012. "Multisensory integration weightings underlying haptic feedback in laparoscopic surgery." Asian Journal of Endoscopic Surgery. 5 (4), p. 207.

Letter

Clinicians' perception of using digital stethoscopes in telehealth platform: Queensland telehealth preliminary study
Soroush, Layla, Hafeez-Baig, Abdul and Gururajan, Raj. 2010. "Clinicians' perception of using digital stethoscopes in telehealth platform: Queensland telehealth preliminary study." Rosemann, Michael (ed.) 21st Australasian Conference on Information Systems (ACIS 2010). Brisbane, Australia 01 - 03 Dec 2010 Brisbane, Australia.

Paper

Theoretical basis for identification of different anesthetic states based on routinely recorded EEG during operation
Nguyen-Ky, T., Wen, Peng and Li, Yan. 2009. "Theoretical basis for identification of different anesthetic states based on routinely recorded EEG during operation." Computers in Biology and Medicine. 39 (1), pp. 40-45. https://doi.org/10.1016/j.compbiomed.2008.10.007

Article

An index of depth of anaesthesia based on wavelet analysis of middle latency auditory evoked potentials
Wang, Zicong, Li, Yingchun, Wen, Peng and Meng, Max Q.-H.. 2007. "An index of depth of anaesthesia based on wavelet analysis of middle latency auditory evoked potentials." 2007 IEEE/ICM International Conference on Complex Medical Engineering (CME 2007). Beijing, China 23 - 27 May 2007 Beijing, China. https://doi.org/10.1109/ICCME.2007.4381758

Paper

Monitoring depth of anaesthesia using auditory evoked potential and bispectrum
Wang, Zicong, Li, Yingchun, Wen, Peng and Meng, Max Q.-H.. 2007. "Monitoring depth of anaesthesia using auditory evoked potential and bispectrum." 2007 IEEE International Conference on Integration Technology. Shenzhen, China 20 - 24 Mar 2007 Shenzhen, China. https://doi.org/10.1109/ICITECHNOLOGY.2007.4290486

Paper

Towards three-dimensional fusion of infrared guidance measurements for biopsy procedures: some preliminary results and design considerations
Sharifi, Behrooz and Leis, John. 2010. "Towards three-dimensional fusion of infrared guidance measurements for biopsy procedures: some preliminary results and design considerations." 2010 4th International Conference on Signal Processing and Communication Systems (ICSPCS 2010). Gold Coast, Australia 13 - 15 Dec 2010 New York, NY. United States. https://doi.org/10.1109/ICSPCS.2010.5709650

Paper

It’s looking up! 3D mapping of foot surface contours
Chong, Albert K.-F., Newsham-West, Richard and Milburn, Peter. 2010. "It’s looking up! 3D mapping of foot surface contours." Lim, C. T. and Goh, J. C. H. (ed.) WCB 2010: 6th World Congress of Biomechanics. Singapore 01 - 06 Aug 2010 Berlin, Germany. https://doi.org/10.1007/978-3-642-14515-5

Poster

Solar ultraviolet radiation incident upon reef snorkelers determined by consideration of the partial immersion of dosimeters in the natural ocean environment
Downs, Nathan, Parisi, Alfio and Schouten, Peter. 2011. "Solar ultraviolet radiation incident upon reef snorkelers determined by consideration of the partial immersion of dosimeters in the natural ocean environment." Measurement Science and Technology. 22 (1), pp. 1-9. https://doi.org/10.1088/0957-0233/22/1/015801

Article

Phenothiazine UVA dosimeter: characteristics and performance
Jia, Keqin, Parisi, Alfio V. and Kimlin, Michael G.. 2010. "Phenothiazine UVA dosimeter: characteristics and performance." Photochemical and Photobiological Sciences. 9 (9), pp. 1224-1227. https://doi.org/10.1039/c0pp00094a

Article

Robust internal model control for depth of anaesthesia
Abdulla, Shahab Anna and Wen, Peng. 2011. "Robust internal model control for depth of anaesthesia." International Journal of Mechatronics and Automation. 1 (1), pp. 1-8. https://doi.org/10.1504/IJMA.2011.039150

Article

Techniques for solar dosimetry in different environments
Parisi, Alfio V., Turnbull, David J., Schouten, Peter, Downs, Nathan and Turner, Joanna. 2010. "Techniques for solar dosimetry in different environments." Gao, Wei, Schmoldt, Daniel L. and Slusser, James R. (ed.) UV radiation in global climate change: measurements, modeling and effects on ecosystems. Heidelberg, Germany. Springer. pp. 192-204

Edited book (chapter)