Depth of anaesthesia assessment using interval second-order difference plot and permutation entropy techniques
Article
Article Title | Depth of anaesthesia assessment using interval second-order difference plot and permutation entropy techniques |
---|---|
ERA Journal ID | 41674 |
Article Category | Article |
Authors | Li, Tianning (Author) and Wen, Peng (Author) |
Journal Title | IET Signal Processing |
Journal Citation | 11 (2), pp. 221-227 |
Number of Pages | 7 |
Year | 2017 |
Place of Publication | United Kingdom |
ISSN | 1751-9675 |
Digital Object Identifier (DOI) | https://doi.org/10.1049/iet-spr.2015.0114 |
Web Address (URL) | http://digital-library.theiet.org/content/journals/10.1049/iet-spr.2015.0114 |
Abstract | This study presents a new method to apply the interval second-order difference plot (ISODP) and interval permutation entropy (IPE) techniques to assess the depth of anaesthesia (DoA). First, the denoised electroencephalograph signals are decomposed into 13 different frequency bands. The second-order difference plot (SODP) and permutation entropy (PE) values of each frequency band are calculated. The SODP and PE values of high-frequency bands (21.5-47 Hz) show the highest linear relationship with the anaesthesia states, therefore they are selected to form the parameter set. Then the SODP and PE parameters are fine tuned using the interval feature technique. Finally, a new index is designed using the ISODP and IPE. The new index is evaluated and compared with measured bispectral (BIS). The results show that there is a very close correlation between the proposed index and the BIS during different anaesthetic states. The new index also shows an earlier time response (3.1–59.7 s) than BIS during the change of anaesthetic states. In addition, the proposed index is able to continuously assess the DoA of patients when the quality of signal is poor and the BIS does not have any valid outputs. |
Keywords | depth of anesthesia (DoA), second order different plot (SODP), Permutation entropy, Interval feature method |
ANZSRC Field of Research 2020 | 469999. Other information and computing sciences not elsewhere classified |
400399. Biomedical engineering not elsewhere classified | |
400305. Biomedical instrumentation | |
Public Notes | Files associated with this item cannot be displayed due to copyright restrictions. |
Byline Affiliations | School of Agricultural, Computational and Environmental Sciences |
Institution of Origin | University of Southern Queensland |
https://research.usq.edu.au/item/q3qwz/depth-of-anaesthesia-assessment-using-interval-second-order-difference-plot-and-permutation-entropy-techniques
1673
total views20
total downloads3
views this month0
downloads this month