Monitoring depth of anaesthesia using auditory evoked potential and bispectrum
Paper
Paper/Presentation Title | Monitoring depth of anaesthesia using auditory evoked potential and bispectrum |
---|---|
Presentation Type | Paper |
Authors | Wang, Zicong (Author), Li, Yingchun (Author), Wen, Peng (Author) and Meng, Max Q.-H. (Author) |
Journal or Proceedings Title | Proceedings of the 2007 IEEE International Conference on Integration Technology |
Number of Pages | 5 |
Year | 2007 |
Place of Publication | Shenzhen, China |
ISBN | 1424410924 |
Digital Object Identifier (DOI) | https://doi.org/10.1109/ICITECHNOLOGY.2007.4290486 |
Web Address (URL) of Paper | https://ieeexplore.ieee.org/document/4290486 |
Web Address (URL) of Conference Proceedings | https://ieeexplore.ieee.org/xpl/conhome/4290335/proceeding |
Conference/Event | 2007 IEEE International Conference on Integration Technology |
Event Details | 2007 IEEE International Conference on Integration Technology Event Date 20 to end of 24 Mar 2007 Event Location Shenzhen, China |
Abstract | In this study, two methods, Auditory Evoked Potential (AEP) and bispectrum, based on EEG signal processing are employed in monitoring depth of anaesthesia. Auditory evoked potential is obtained using wavelet analysis in order to achieve a fast extraction. Both AEP and bispectrum methods show good relativity with the depth of anaesthesia. Besides, both methods are integrated in a software developed on a personal computer to help those non-specialists to apply the results easily. |
Keywords | anaesthesia, depth of anaesthesia, EEG, AEP, bispectrum |
ANZSRC Field of Research 2020 | 320602. Medical biotechnology diagnostics (incl. biosensors) |
400305. Biomedical instrumentation | |
Public Notes | © 2007 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. |
Byline Affiliations | Shenzhen Institute of Advanced Technology, China |
Department of Electrical, Electronic and Computer Engineering | |
Chinese University of Hong Kong, China |
https://research.usq.edu.au/item/9y514/monitoring-depth-of-anaesthesia-using-auditory-evoked-potential-and-bispectrum