The effect of shear span-to-depth ratio and test set-up on the behavior of fibre composite sandwich structure
Paper
Paper/Presentation Title | The effect of shear span-to-depth ratio and test set-up on the behavior of fibre composite sandwich structure |
---|---|
Presentation Type | Paper |
Authors | |
Author | Manalo, A. C. |
Editors | Al-Mahaidi, Riadh, Smith, Scott T., Bai, Yu and Zhao, Xiao-Ling |
Journal or Proceedings Title | Proceedings of the 4th Asia-Pacific Conference on FRP in Structures (APFIS 2013) |
ERA Conference ID | 50255 |
Number of Pages | 6 |
Year | 2013 |
Place of Publication | Melbourne, Australia |
ISBN | 9780987593016 |
Web Address (URL) of Paper | http://www.apfis2013.org/ |
Conference/Event | 4th Asia-Pacific Conference on FRP in Structures (APFIS 2013): Towards Sustainable Infrastructure with FRP Composites |
Asia-Pacific Conference on FRP in Structures | |
Event Details | 4th Asia-Pacific Conference on FRP in Structures (APFIS 2013): Towards Sustainable Infrastructure with FRP Composites Event Date 11 to end of 13 Dec 2013 Event Location Melbourne, Australia |
Event Details | Asia-Pacific Conference on FRP in Structures APFIS |
Abstract | The shear strength of the core material is a critical parameter and is an important consideration when designing a composite sandwich structure in construction application. In this paper, the shear behaviour of a new generation composite sandwich panel made up of glass fibre composite skins and phenolic core was investigated under three-point loading short beam (SB) and asymmetrical beam shear (ABS) tests. The effect of the shear span-to-depth ratio (a/D) was examined on the shear strength and failure behaviour of the fibre composite sandwich beams. The results showed that the shear behaviour of the beams is affected strongly by the a/D ratios. The beams with a lower a/D ratio failed at a higher load compare to the beams with larger a/D ratio. In general, the sandwich beams tested under ABS failed at a significantly higher load than that of the sandwich beams tested under SB for the same a/D ratio. The results also showed that the behaviour of the fibre composite sandwich beams is governed by the strength of the phenolic core material. In all the tested sandwich beams, the failure of the core occurred under the loading point where the shear force and bending moment are maximum. |
Keywords | fibre composites; sandwich beams; shear; shear span-to-depth ratio; short beam; asymmetrical beam |
ANZSRC Field of Research 2020 | 400510. Structural engineering |
401602. Composite and hybrid materials | |
401706. Numerical modelling and mechanical characterisation | |
Public Notes | Files associated with this item cannot be displayed due to copyright restrictions. |
Byline Affiliations | Centre of Excellence in Engineered Fibre Composites |
Institution of Origin | University of Southern Queensland |
https://research.usq.edu.au/item/q236x/the-effect-of-shear-span-to-depth-ratio-and-test-set-up-on-the-behavior-of-fibre-composite-sandwich-structure
2317
total views262
total downloads2
views this month0
downloads this month