Effect of spiral spacing and concrete strength on behavior of GFRP-reinforced hollow concrete columns
Article
Article Title | Effect of spiral spacing and concrete strength on |
---|---|
ERA Journal ID | 4221 |
Article Category | Article |
Authors | Alajarmeh, Omar S. (Author), Manalo, Allan C. (Author), Benmokrane, Brahim (Author), Karunasena, Warna (Author) and Mendis, Priyan (Author) |
Journal Title | Journal of Composites for Construction |
Journal Citation | 24 (1), pp. 1-14 |
Article Number | 04019054 |
Number of Pages | 14 |
Year | 2020 |
Publisher | American Society of Civil Engineers |
Place of Publication | United States |
ISSN | 1090-0268 |
1943-5614 | |
Digital Object Identifier (DOI) | https://doi.org/10.1061/(ASCE)CC.1943-5614.0000987 |
Web Address (URL) | https://ascelibrary.org/doi/10.1061/%28ASCE%29CC.1943-5614.0000987 |
Abstract | Hollow concrete columns (HCCs) are one of the preferred construction systems for bridge piers, piles, and poles because they require less material and have a high strength-to-weight ratio. While spiral spacing and concrete compressive strength are two critical design parameters that control HCC behavior, the deterioration of steel reinforcement is becoming an issue for HCCs. This study explored the use of glass fiber-reinforced polymer (GFRP) bars as longitudinal and lateral reinforcement for hollow concrete columns and investigated the effect of various spiral spacing and different concrete compressive strengths (f′c). Seven HCCs with inner and outer diameters of 90 and 250 mm, respectively, and reinforced with six longitudinal GFRP bars, were prepared and tested. The spiral spacing was no spirals, 50, 100, and 150 mm; the f′c varied from 21 to 44 MPa. Test results show that reducing the spiral spacing resulted in increased HCC uniaxial compression capacity, ductility, and confined strength due to the high lateral confining efficiency. Increasing f′c, on the other hand, increased the axial-load capacity but reduced the ductility and confinement efficiency due to the brittle behavior of high compressive-strength concrete. The analytical models considering the axial load contribution of the GFRP bars and the confined concrete core accurately predicted the behavior of the HCCs after the spalling of the concrete cover or at the post-loading behavior. |
Keywords | hollow column; glass fiber-reinforced polymer (GFRP) bar; spiral pacing; concrete compressive strength |
ANZSRC Field of Research 2020 | 400510. Structural engineering |
400505. Construction materials | |
401602. Composite and hybrid materials | |
401707. Solid mechanics | |
Public Notes | File reproduced in accordance with the copyright policy of the publisher/author. |
Byline Affiliations | Centre for Future Materials |
University of Sherbrooke, Canada | |
University of Melbourne | |
Institution of Origin | University of Southern Queensland |
https://research.usq.edu.au/item/q57x0/effect-of-spiral-spacing-and-concrete-strength-on-behavior-of-gfrp-reinforced-hollow-concrete-columns
Download files
305
total views336
total downloads3
views this month8
downloads this month