Understanding the Ageing Aspects of Natural Ester Based Insulation liquid in Power Transformer
Article
Badana, Kapila, Ekanayake, Chandima, Saha, Tapan Kumar and Annamalai, Pratheep Kumar. 2016. "Understanding the Ageing Aspects of Natural Ester Based Insulation liquid in Power Transformer." IEEE Transactions on Dielectrics and Electrical Insulation. 23 (1), pp. 246-257. https://doi.org/10.1109/Tdei.2015.004744
Article Title | Understanding the Ageing Aspects of Natural Ester Based Insulation liquid in Power Transformer |
---|---|
ERA Journal ID | 4449 |
Article Category | Article |
Authors | Badana, Kapila, Ekanayake, Chandima, Saha, Tapan Kumar and Annamalai, Pratheep Kumar |
Journal Title | IEEE Transactions on Dielectrics and Electrical Insulation |
Journal Citation | 23 (1), pp. 246-257 |
Number of Pages | 12 |
Year | 2016 |
Publisher | IEEE (Institute of Electrical and Electronics Engineers) |
Place of Publication | United States |
ISSN | 1070-9878 |
1558-4135 | |
Digital Object Identifier (DOI) | https://doi.org/10.1109/Tdei.2015.004744 |
Web Address (URL) | https://ieeexplore.ieee.org/document/7422567/authors#authors |
Abstract | Cellulose based insulation materials and mineral oils have widely been used in liquid filled transformers. Environmental and fire-safety concerns have accelerated the use of Natural Esters (NE) as a sustainable alternative to mineral oil. There is a rapid growth of their application for distribution level transformers. To ensure a safe and long-term operation of the vegetable oil filled transformers, it is necessary to clarify the knowledge gaps with respect to the ageing of vegetable oil impregnated cellulose and insulation diagnostic methods. The condition monitoring of mineral oil filled transformers has been well characterised, due to the numerous laboratory and field studies conducted during the past several decades. The application of these available condition monitoring techniques for NE filled transformers is yet to be validated as the use of NE for power transformers is in the evaluation stage. In this paper the performance of NE as insulation in transformers by evaluating the ageing of NE impregnated cellulose pressboard is presented. For this purpose, an accelerated ageing experiment has been carried out in sealed tubes at 120 °C. The ageing of oil impregnated pressboard has been characterised by decrease in the degree of polymerisation (DP) of pressboard, and the formation of both 2-furfuraldehyde and dissolved carbon dioxide (CO2) in the oil. The structural changes of cellulose have been supported by Fourier Transform Infrared (FTIR) spectra. Moreover, the results have been compared with cellulose insulation samples aged under similar conditions in conventional mineral oil. Acidity value, dissipation factor and viscosity measurements have been used to compare the stability of NE in a transformer operating environment to mineral oil. |
Keywords | cellulose |
Contains Sensitive Content | Does not contain sensitive content |
ANZSRC Field of Research 2020 | 340302. Macromolecular materials |
Public Notes | Files associated with this item cannot be displayed due to copyright restrictions. |
Byline Affiliations | University of Queensland |
Permalink -
https://research.usq.edu.au/item/z23qv/understanding-the-ageing-aspects-of-natural-ester-based-insulation-liquid-in-power-transformer
42
total views0
total downloads2
views this month0
downloads this month