Manufacturing of a parabolic trough concentrating collector test rig and a “LASER-Screen” technique for measuring actual focal length and light interceptance of the collector
Paper
Paper/Presentation Title | Manufacturing of a parabolic trough concentrating collector test rig and a “LASER-Screen” technique for measuring actual focal length and light interceptance of the collector |
---|---|
Presentation Type | Paper |
Authors | Islam, Majedul, Mohiuddin, Sadi, Limon, Amir Hamza, Faruque, Md Omar and Yarlagadda, Prasad K.D.V. |
Journal or Proceedings Title | Procedia Manufacturing |
Journal Citation | 30, pp. 404-410 |
Number of Pages | 7 |
Year | 2019 |
Publisher | Elsevier |
Place of Publication | Netherlands |
ISSN | 2351-9789 |
Digital Object Identifier (DOI) | https://doi.org/10.1016/j.promfg.2019.02.056 |
Web Address (URL) of Paper | https://www.sciencedirect.com/science/article/pii/S2351978919300861 |
Web Address (URL) of Conference Proceedings | https://www.sciencedirect.com/journal/procedia-manufacturing/vol/30/suppl/C |
Conference/Event | 14th Global Congress on Manufacturing and Management (GCMM 2018) |
Event Details | 14th Global Congress on Manufacturing and Management (GCMM 2018) Parent Global Congress on Manufacturing & Management (GCMM) Delivery In person Event Date 05 to end of 07 Dec 2018 Event Location Brisbane, Australia Event Web Address (URL) |
Abstract | A portable parabolic trough-concentrating solar collector test rig was designed, and fabricated using locally available materials and technique. A trough made of any materials and the energy collection element of any geometry with maximum aperture area of 80×100cm2 and 2.5×100cm2 respectively can be fitted readily in the support structure of the rig. A two-axis manual tracking system allows the rig to track the sun daily from east to west for every 5° interval, and seasonally from 50°North to 80°South for every 15°. In addition to this, actual focal length and light interceptance were investigated applying customised “LASER-Screen” technique. An average light interceptance of the rig for a 2.5 cm diameter absorber tube was measured to be 85.9%. The focal length of the 100 cm long test rig was found to be 18.167±1.35cm. The test rig will facilitate to investigate the energy potential in Chittagong region of Bangladesh. |
Keywords | Parabolic trough concentrating collector; concentrating solar power; parabolic profile accuracy; slope error measurement; LASER Screen technique |
ANZSRC Field of Research 2020 | 4014. Manufacturing engineering |
Byline Affiliations | Chittagong University of Engineering and Technology, Bangladesh |
Queensland University of Technology |
https://research.usq.edu.au/item/y1876/manufacturing-of-a-parabolic-trough-concentrating-collector-test-rig-and-a-laser-screen-technique-for-measuring-actual-focal-length-and-light-interceptance-of-the-collector